V 3.13.0 (2024-01-08) - The manually entered maximum depth for measuring points in the vertical without depth measurement was not applied correctly. The resulting error when calculating the missing percentage depth has been fixed. - Correction of an error that occurs if the MFPro file does not have an explicitly marked last edge point. - Import MFPro files with imperial units: error when converting units has been fixed. V 3.12.0 - Internal version; not published. V 3.11.0 (2022-03-15) - Fixed rounding problem when opening MFPro files converted to ADC files. - Suppresses the creation of raw point data for MFPro files when converting to ADC files. - If the ADC file is opened before the MFPro file, the software disables additional ADC tabs. - "Standard Deviation" field disabled in the Overview tab for MFPro data. V 3.10.0 (2020-03-24) - Improved graphical display of the percentage of partial discharges in the cross-section. - Various bug fixes in the XML output file for the "Biber" software. - Optimized measured value output (extended number of decimal places for various parameters). - Automatic date format recognition during import; based on the operating system used. - Original MF per measurement data file is no longer overwritten during recalculation. Instead, QReview creates a new file with the extension "_recalc.tsv". - Number of digits for area and average speed display changed when importing MF per file. – Various software optimizations and bug fixes. V 3.09.8 (2018-11-23) - Various adjustments for the OTT MF pro Firmware V 2.0. V 3.03.0 ... V 3.09.7 – Internal versions; not published. V 3.02.0 (2018-01-29) - Display of imperial units for Qliner measured values corrected. - A picture of the MF-Pro has been added to the file selection menu. - If "Width" of the bottom axis scaling of diagrams is set to "zero", QReview will do the scaling of the bottom axis automatically. - Scaling for imperial units in the vertical profile chart has been fixed. - The Min/Max-scaling in the vertical profile chart is now based only on "good" cells. - A window for text-based review of measured values has been added in the function "Text Export of Qliner data". - Increased accuracy of text export of ADC measured values when discharge is very small. V 3.01.4 ... V 3.01.5 – Internal versions; not published V 3.01.3 (2015-09-22) - Enables data post-processing of OTT MF-pro output files of version V 1.4.0.0 (or higher). (Measurement time for each station has been added to the summary report of the OTT MF-pro output files) – Various minor software optimizations V 3.01.0 ... V 3.01.2 – Internal versions V 3.00.5 (2015-11-30) – Bugfix (communication with OTT ADC). V 3.00.4 (2014-09-30) – New function: editing of recorded values of the magnetic-inductive current meter OTT MF pro; · opening of measurement data files (import) · editing of measured values · exporting measured values in XML format – Various software optimisations and bugfixes V 2.47.0 ... V 3.00.3 - Internal versions V 2.46.0 (2012-06-26) – Various bugfixes.